{"id":783,"date":"2026-06-23T09:47:07","date_gmt":"2026-06-23T09:47:07","guid":{"rendered":"https:\/\/oldhamcoupling.net\/product\/ep6c-40-precision-clamp-oldham-coupling\/"},"modified":"2026-06-24T08:47:43","modified_gmt":"2026-06-24T08:47:43","slug":"ep6c-40-precision-clamp-oldham-coupling","status":"publish","type":"product","link":"https:\/\/oldhamcoupling.net\/pl\/produkt\/ep6c-40-precision-clamp-oldham-coupling\/","title":{"rendered":"EP6C-40 Precision Clamp Oldham Coupling"},"content":{"rendered":"<div style=\"font-family:Arial,sans-serif; font-size:clamp(14px,2vw + 10px,18px); line-height:1.7; color:#1f2937; word-break:break-word; overflow-wrap:break-word;\">\n<h2 style=\"color:#5b21b6; font-size:clamp(20px,3vw + 10px,28px); border-bottom:3px solid #5b21b6; padding-bottom:calc(0.4em); margin-top:calc(1em);\">EP6C-40 Precision Clamp-Hub Oldham Coupling \u2014 40 mm Aluminum Hub for Larger Servo and Medical Imaging Drives<\/h2>\n<p>The <strong>EP6C-40 precision clamp Oldham coupling<\/strong> brings the clamp-hub architecture into the duty class of larger-bore servo drives. With 9 N\u00b7m continuous \/ 18 N\u00b7m peak torque rating, 40 mm hub OD, 12\u201316 mm bore range, and 3 600 rpm permissible speed, the EP6C-40 is sized for the precision indexing and rotational-positioning systems that dominate modern medical imaging, semiconductor front-end equipment, and higher-end CNC machine tool spindle\/auxiliary axes. The clamp-hub mounting architecture \u2014 distinguishing this product from the corresponding EP6-40 set-screw variant \u2014 eliminates shaft marking entirely, supports unlimited removal-and-reinstall cycles, and accommodates hardened-shaft installations (HRC &gt;50) that set-screw mounting cannot grip reliably.<\/p>\n<p>For OEM equipment designers specifying the EP6C-40, the clamp-mount advantage matters in three specific application contexts. First, on encoder-feedback servo systems where hub re-positioning during commissioning, service, or upgrade events is routine \u2014 set-screw marking accumulates incremental damage to the shaft surface, while clamp-mount preserves dimensional accuracy across unlimited cycles. Second, on hardened-shaft installations \u2014 typical of larger industrial servos, medical-imaging slip-ring assemblies, and semiconductor wafer-handling robots \u2014 where the substrate hardness exceeds the bite-in capability of set-screws. Third, in cleanroom and pharma-adjacent production environments where shaft marking represents a contamination-risk source and validation barrier. The EP6C-40 addresses all three of these application classes with a single catalogue specification.<\/p>\n<h3 style=\"color:#5b21b6; font-size:clamp(17px,2.5vw + 10px,22px); margin-top:calc(1.2em);\">Specifications<\/h3>\n<div style=\"overflow-x:auto; padding:3% 0;\">\n<table style=\"width:100%; border-collapse:collapse; min-width:520px;\">\n<thead>\n<tr style=\"background:#5b21b6; color:#fff;\">\n<th style=\"padding:calc(0.5em); text-align:left; border:1px solid #5b21b6;\">Parameter<\/th>\n<th style=\"padding:calc(0.5em); text-align:left; border:1px solid #5b21b6;\">Value<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding:calc(0.5em); border:1px solid #d1d5db;\">Model<\/td>\n<td style=\"padding:calc(0.5em); border:1px solid #d1d5db;\">EP6C-40<\/td>\n<\/tr>\n<tr style=\"background:#ede9fe;\">\n<td style=\"padding:calc(0.5em); border:1px solid #d1d5db;\">Continuous Torque (Tn)<\/td>\n<td style=\"padding:calc(0.5em); border:1px solid #d1d5db;\">9 N\u00b7m<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:calc(0.5em); border:1px solid #d1d5db;\">Peak Torque (Tmax)<\/td>\n<td style=\"padding:calc(0.5em); border:1px solid #d1d5db;\">18 N\u00b7m<\/td>\n<\/tr>\n<tr style=\"background:#ede9fe;\">\n<td style=\"padding:calc(0.5em); border:1px solid #d1d5db;\">Permissible Speed (n)<\/td>\n<td style=\"padding:calc(0.5em); border:1px solid #d1d5db;\">3 600 rpm<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:calc(0.5em); border:1px solid #d1d5db;\">Bore Range (d)<\/td>\n<td style=\"padding:calc(0.5em); border:1px solid #d1d5db;\">12 \u2013 16 mm<\/td>\n<\/tr>\n<tr style=\"background:#ede9fe;\">\n<td style=\"padding:calc(0.5em); border:1px solid #d1d5db;\">Outside Diameter (D)<\/td>\n<td style=\"padding:calc(0.5em); border:1px solid #d1d5db;\">40 mm<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:calc(0.5em); border:1px solid #d1d5db;\">Overall Length (L)<\/td>\n<td style=\"padding:calc(0.5em); border:1px solid #d1d5db;\">52 mm<\/td>\n<\/tr>\n<tr style=\"background:#ede9fe;\">\n<td style=\"padding:calc(0.5em); border:1px solid #d1d5db;\">Clamp Bolt Size<\/td>\n<td style=\"padding:calc(0.5em); border:1px solid #d1d5db;\">M5 (2 per hub)<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:calc(0.5em); border:1px solid #d1d5db;\">Clamp Bolt Torque<\/td>\n<td style=\"padding:calc(0.5em); border:1px solid #d1d5db;\">6 N\u00b7m<\/td>\n<\/tr>\n<tr style=\"background:#ede9fe;\">\n<td style=\"padding:calc(0.5em); border:1px solid #d1d5db;\">Radial Misalignment (\u0394y)<\/td>\n<td style=\"padding:calc(0.5em); border:1px solid #d1d5db;\">0.5 mm<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:calc(0.5em); border:1px solid #d1d5db;\">Angular Misalignment (\u0394\u03b1)<\/td>\n<td style=\"padding:calc(0.5em); border:1px solid #d1d5db;\">1\u00b0<\/td>\n<\/tr>\n<tr style=\"background:#ede9fe;\">\n<td style=\"padding:calc(0.5em); border:1px solid #d1d5db;\">Axial Misalignment (\u0394x)<\/td>\n<td style=\"padding:calc(0.5em); border:1px solid #d1d5db;\">0.5 mm<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:calc(0.5em); border:1px solid #d1d5db;\">Mass<\/td>\n<td style=\"padding:calc(0.5em); border:1px solid #d1d5db;\">95 g<\/td>\n<\/tr>\n<tr style=\"background:#ede9fe;\">\n<td style=\"padding:calc(0.5em); border:1px solid #d1d5db;\">Backlash<\/td>\n<td style=\"padding:calc(0.5em); border:1px solid #d1d5db;\">Zero<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:calc(0.5em); border:1px solid #d1d5db;\">Operating Temperature<\/td>\n<td style=\"padding:calc(0.5em); border:1px solid #d1d5db;\">-30 \u00b0C to +80 \u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"text-align:center; padding:calc(1em) 0;\"><img decoding=\"async\" src=\"https:\/\/oldhamcoupling.net\/wp-content\/uploads\/2026\/06\/clamp-type-oldham-coupling-specification.webp\" alt=\"EP6C-40 precision clamp oldham coupling dimensional specification\" style=\"max-width:100%; height:auto;\"><\/p>\n<h3 style=\"color:#5b21b6; font-size:clamp(17px,2.5vw + 10px,22px); margin-top:calc(1.2em);\">Materials<\/h3>\n<div style=\"display:flex; flex-wrap:wrap; gap:calc(1%); padding:3% 0;\">\n<div style=\"width:100%; max-width:400px; background:#f5f3ff; border-left:4px solid #5b21b6; padding:calc(3%); margin-bottom:calc(1em); word-break:break-word; overflow-wrap:break-word;\">\n<h4 style=\"margin-top:0; color:#5b21b6;\">2A12 \/ 7075 Aluminum Clamp Hubs<\/h4>\n<p>Hubs are precision-machined from 2A12 aluminum alloy (or 7075-T6 for high-strength duty deployments) and anodised to mid-gloss black or natural finish. The split-collar clamp section is engineered with a 3\u00d7 safety factor against the M5 clamp-bolt torque-induced hoop stress. Hub material delivers low mass (essential for low reflected-inertia in servo-feedback loops), substantial corrosion resistance, and full machinability for custom-bore variants on engineering enquiry.<\/p>\n<\/p><\/div>\n<div style=\"width:100%; max-width:400px; background:#f5f3ff; border-left:4px solid #5b21b6; padding:calc(3%); margin-bottom:calc(1em); word-break:break-word; overflow-wrap:break-word;\">\n<h4 style=\"margin-top:0; color:#5b21b6;\">POM-C Self-Lubricating Slider<\/h4>\n<p>The cross-slider is precision-injection-moulded from POM-C acetal polymer with PTFE additive for self-lubrication. No external grease is required across the full -30 \u00b0C to +80 \u00b0C operating temperature range. POM-C delivers low friction coefficient against the aluminum hub slots (typical 0.15\u20130.25), inherent vibration damping, and electrical-isolation between drive shaft and driven shaft. The polymer slider is the wear part \u2014 replacement typically occurs at 5\u20138 year intervals under typical servo duty.<\/p>\n<\/p><\/div>\n<div style=\"width:100%; max-width:400px; background:#f5f3ff; border-left:4px solid #5b21b6; padding:calc(3%); margin-bottom:calc(1em); word-break:break-word; overflow-wrap:break-word;\">\n<h4 style=\"margin-top:0; color:#5b21b6;\">Class 12.9 Clamp Bolt Hardware<\/h4>\n<p>Standard clamp-bolt hardware is M5 socket-head cap-screw to ISO 4762, property class 12.9, electro-galvanic-zinc plated. For stainless-steel hub variants, A4-80 stainless clamp hardware is supplied. Clamp-bolt torque specification (6 N\u00b7m) provides sufficient hub-to-shaft clamp force for the rated 18 N\u00b7m peak transmission without exceeding the aluminum hub&#8217;s elastic-limit. Replacement clamp-bolt sets stocked under part EP6C-40-BOLT for emergency-replacement service.<\/p>\n<\/p><\/div>\n<\/div>\n<h3 style=\"color:#5b21b6; font-size:clamp(17px,2.5vw + 10px,22px); margin-top:calc(1.2em);\">Engineering for Larger Servo-Feedback Loops<\/h3>\n<p>At the EP6C-40&#8217;s bore range (12\u201316 mm) and rated torque (18 N\u00b7m peak), the coupling is typically integrated into servo-feedback control loops where its mechanical characteristics affect the broader system&#8217;s positioning accuracy and dynamic-response profile. The zero-backlash transmission is essential: any angular lash between motor encoder and driven-axis position introduces oscillation modes that the servo controller must compensate for, ultimately limiting achievable positioning resolution. The EP6C-40&#8217;s cross-slider architecture delivers true zero-backlash \u2014 not the residual elastic-windup of an elastomer-spider coupling, not the angular dead-band of even a precision-machined disc-pack design.<\/p>\n<p>The substantial misalignment envelope (0.5 mm parallel, 1\u00b0 angular) addresses the realistic frame-tolerance accumulation of larger-bore servo installations. A 12 mm encoder shaft to a 16 mm reducer output shaft typically involves a motor mounting flange, a reducer mounting flange, and an intermediate bracket \u2014 each with its own dimensional tolerance stack-up. The EP6C-40&#8217;s misalignment budget comfortably absorbs the cumulative tolerance without imposing radial loads on the encoder bearings or the reducer output bearings, preserving the life expectancy of both. This is meaningfully better than the typical 0.05 mm parallel envelope of bellows couplings, which require precision laser-alignment to maintain.<\/p>\n<p>For engineering guidance on integrating EP6C-class couplings into servo-feedback control architectures, see <a href=\"https:\/\/oldhamcoupling.net\/pl\/\" style=\"color:#5b21b6; text-decoration:underline;\">Ever-power&#8217;s precision-coupling engineering portal<\/a>.<\/p>\n<p style=\"text-align:center; padding:calc(1em) 0;\"><img decoding=\"async\" src=\"https:\/\/oldhamcoupling.net\/wp-content\/uploads\/2026\/06\/clamp-vs-set-screw-oldham-coupling.webp\" alt=\"EP6C-40 precision clamp oldham coupling vs set screw comparison\" style=\"max-width:100%; height:auto;\"><\/p>\n<h3 style=\"color:#5b21b6; font-size:clamp(17px,2.5vw + 10px,22px); margin-top:calc(1.2em);\">Industry Applications<\/h3>\n<div style=\"display:flex; flex-wrap:wrap; gap:calc(1%); padding:3% 0;\">\n<div style=\"width:100%; max-width:400px; background:#fff; border:1px solid #e5e7eb; border-radius:calc(0.5em); padding:calc(3%); margin-bottom:calc(1em);\">\n<h4 style=\"color:#5b21b6; margin-top:0;\"><span style=\"font-size:1.4em;\"> <\/span> Medical Imaging Indexing<\/h4>\n<p>CT-scanner gantry-indexing drives, MRI patient-table positioning, and PET-scanner detector-rotation axes. Clamp-mount preserves hardened shaft surface across service-life and major-equipment overhaul cycles.<\/p>\n<\/p><\/div>\n<div style=\"width:100%; max-width:400px; background:#fff; border:1px solid #e5e7eb; border-radius:calc(0.5em); padding:calc(3%); margin-bottom:calc(1em);\">\n<h4 style=\"color:#5b21b6; margin-top:0;\"><span style=\"font-size:1.4em;\"> <\/span> Semiconductor Front-End<\/h4>\n<p>Wafer-handling robot wrist and elbow axes, EFEM (Equipment Front-End Module) load-port mechanisms, and CMP (chemical-mechanical-polishing) platen-rotation drives. Cleanroom-class shaft preservation through clamp mounting.<\/p>\n<\/p><\/div>\n<div style=\"width:100%; max-width:400px; background:#fff; border:1px solid #e5e7eb; border-radius:calc(0.5em); padding:calc(3%); margin-bottom:calc(1em);\">\n<h4 style=\"color:#5b21b6; margin-top:0;\"><span style=\"font-size:1.4em;\"> <\/span> Robotic Joint Axes<\/h4>\n<p>SCARA-robot wrist-axis and shoulder-axis drives, collaborative-robot middle-axis joints, and articulated-arm-robot J5\/J6 (wrist\/end-effector) drives. Zero-backlash supports high-precision repeatability.<\/p>\n<\/p><\/div>\n<div style=\"width:100%; max-width:400px; background:#fff; border:1px solid #e5e7eb; border-radius:calc(0.5em); padding:calc(3%); margin-bottom:calc(1em);\">\n<h4 style=\"color:#5b21b6; margin-top:0;\"><span style=\"font-size:1.4em;\">\u2699\ufe0f<\/span> Higher-End CNC Auxiliary<\/h4>\n<p>Auxiliary axis drives on CNC machining centres \u2014 tool-changer indexing, automatic-pallet-shuttle rotation, and rotary-table B-axis indexing for 4\/5-axis machining. POM-C slider dampens machine-tool vibration coupling.<\/p>\n<\/p><\/div>\n<div style=\"width:100%; max-width:400px; background:#fff; border:1px solid #e5e7eb; border-radius:calc(0.5em); padding:calc(3%); margin-bottom:calc(1em);\">\n<h4 style=\"color:#5b21b6; margin-top:0;\"><span style=\"font-size:1.4em;\"> <\/span> Optical Inspection Systems<\/h4>\n<p>Industrial machine-vision gantry drives, AOI (automated optical inspection) system camera-positioning axes, and scientific microscopy stage drives. POM-C slider provides vibration-isolation for sensitive optics.<\/p>\n<\/p><\/div>\n<div style=\"width:100%; max-width:400px; background:#fff; border:1px solid #e5e7eb; border-radius:calc(0.5em); padding:calc(3%); margin-bottom:calc(1em);\">\n<h4 style=\"color:#5b21b6; margin-top:0;\"><span style=\"font-size:1.4em;\"> <\/span> Pharma Tablet Press Indexing<\/h4>\n<p>Tablet-press turret indexing drives and capsule-filling-machine main rotation axes. POM-C slider material is USP Class VI compatible; no contaminating lubricant in the load path.<\/p>\n<\/p><\/div>\n<\/div>\n<h3 style=\"color:#5b21b6; font-size:clamp(17px,2.5vw + 10px,22px); margin-top:calc(1.2em);\">Why Choose Ever-power<\/h3>\n<div style=\"background:#f5f3ff; border-radius:calc(0.6em); padding:calc(3%); margin:calc(1em) 0; word-break:break-word; overflow-wrap:break-word;\">\n<h4 style=\"color:#5b21b6; margin-top:0;\">Quality &amp; Compliance<\/h4>\n<p>EP6C-40 production runs under <strong>ISO 9001:2015<\/strong>. Standard documentation pack covers <strong>RoHS<\/strong>, <strong>REACH<\/strong>, and <strong>CE<\/strong> conformity. For pharma customers, USP Class VI compatibility documentation is supplied for the POM-C slider material. For medical-equipment customers, supplementary documentation supporting ISO 13485 medical-device QMS integration is available. For semiconductor cleanroom installations, particulate-emission documentation per SEMI standards is supplied on request.<\/p>\n<h4 style=\"color:#5b21b6;\">Customisation<\/h4>\n<p>Catalogue bore range 12\u201316 mm; custom-bore variants from 10 mm to 18 mm produced under engineering review with 2-week lead time. Imperial-bore variants (1\/2&#8243;, 5\/8&#8243;) supported. 7075-T6 high-strength aluminum hub variant for elevated-temperature-cycling deployments. Anti-static carbon-filled POM-C slider for ATEX Zone 2 and static-sensitive electronics manufacture. A4-80 stainless clamp-bolt hardware for corrosive-ambient installations.<\/p>\n<h4 style=\"color:#5b21b6;\">Aftermarket<\/h4>\n<p>EP6C-40 slider plates and clamp-bolt sets stocked for 1-business-day shipment. 95 g mass per coupling supports air-freight standard for emergency-replacement service. English-speaking engineering desk responds within <strong>24 hours<\/strong>. For OEM partners, customer-nominated buffer-stock arrangements supported with 24-hour replenishment SLAs.<\/p>\n<\/div>\n<p style=\"text-align:center; padding:calc(1em) 0;\"><img decoding=\"async\" src=\"https:\/\/oldhamcoupling.net\/wp-content\/uploads\/2026\/06\/oldham-coupling-factory.webp\" alt=\"Ever-power precision coupling production facility\" style=\"max-width:100%; height:auto;\"><\/p>\n<h3 style=\"color:#5b21b6; font-size:clamp(17px,2.5vw + 10px,22px); margin-top:calc(1.2em);\">Customer Reviews &amp; Case Studies<\/h3>\n<div style=\"display:flex; flex-wrap:wrap; gap:calc(1%); padding:3% 0;\">\n<div style=\"width:100%; max-width:400px; background:#fff; border:1px solid #e5e7eb; border-radius:calc(0.5em); padding:calc(3%); margin-bottom:calc(1em);\">\n<p style=\"color:#f59e0b; font-size:1.3em; margin:0;\">\u2605\u2605\u2605\u2605\u2605<\/p>\n<h4 style=\"color:#5b21b6; margin:calc(0.3em) 0;\">Albania \u2014 Medical-Imaging Service Provider<\/h4>\n<p><em>Used in:<\/em> CT-scanner gantry-indexing drive replacement on a hospital diagnostic-imaging service installation.<\/p>\n<p><em>Feedback:<\/em> &#8220;Original OEM coupling specification was a bellows design that required precision laser-alignment after every service event. Cumulative service-time for alignment was unsustainable for our service-cycle economics. Switched to the EP6C-40 across the installed base \u2014 alignment time reduced by approximately 75 %, with no impact on imaging-accuracy specifications. Excellent retrofit solution for our service workflow.&#8221;<\/p>\n<\/p><\/div>\n<div style=\"width:100%; max-width:400px; background:#fff; border:1px solid #e5e7eb; border-radius:calc(0.5em); padding:calc(3%); margin-bottom:calc(1em);\">\n<p style=\"color:#f59e0b; font-size:1.3em; margin:0;\">\u2605\u2605\u2605\u2605\u2605<\/p>\n<h4 style=\"color:#5b21b6; margin:calc(0.3em) 0;\">Moldova \u2014 Semiconductor-Assembly OEM<\/h4>\n<p><em>Used in:<\/em> EFEM load-port wafer-handling robot wrist-axis drive on a wafer-test assembly cell.<\/p>\n<p><em>Feedback:<\/em> &#8220;Hardened-steel wrist shaft (HRC 58) was not compatible with our previous set-screw coupling specification \u2014 set-screws could not bite into the surface and required Loctite supplementary retention. The EP6C-40 clamp-hub eliminates the problem entirely. Three years of three-shift duty across 40 wafer-handling cells without coupling-attributable failure. Specification has been replicated across our subsequent equipment generations.&#8221;<\/p>\n<\/p><\/div>\n<div style=\"width:100%; max-width:400px; background:#fff; border:1px solid #e5e7eb; border-radius:calc(0.5em); padding:calc(3%); margin-bottom:calc(1em);\">\n<p style=\"color:#f59e0b; font-size:1.3em; margin:0;\">\u2605\u2605\u2605\u2605\u2606<\/p>\n<h4 style=\"color:#5b21b6; margin:calc(0.3em) 0;\">Armenia \u2014 Precision-Optics Manufacturer<\/h4>\n<p><em>Used in:<\/em> Optical-grinding spindle auxiliary-drive coupling on a precision lens-grinding production line.<\/p>\n<p><em>Feedback:<\/em> &#8220;Optical-grinding application requires extreme vibration-isolation between drive motor and spindle. The EP6C-40&#8217;s POM-C slider has performed excellently in damping motor-side vibration content from reaching the grinding-spindle bearings. Knock one star only because the initial M5 clamp-bolt torque guidance (6 N\u00b7m) was not as prominently called out in our shipping documentation as we would have preferred \u2014 initial install at site torqued too high and required corrective re-torquing. Otherwise excellent.&#8221;<\/p>\n<\/p><\/div>\n<\/div>\n<h3 style=\"color:#5b21b6; font-size:clamp(17px,2.5vw + 10px,22px); margin-top:calc(1.2em);\">Frequently Asked Questions<\/h3>\n<details style=\"background:#f5f3ff; border:1px solid #c4b5fd; border-radius:calc(0.4em); padding:calc(1.5%); margin-bottom:calc(0.6em);\">\n<summary style=\"cursor:pointer; font-weight:bold; color:#5b21b6; padding:calc(0.5em);\">Why specify clamp-mount instead of set-screw at this size?<\/summary>\n<p style=\"padding:calc(0.5em);\">Three engineering drivers: (1) hardened-shaft compatibility \u2014 set-screws cannot bite into shafts above HRC 50, which is standard for larger industrial servo motor outputs; (2) shaft-mark elimination \u2014 clamp-mount preserves shaft dimensional accuracy across unlimited removal-and-reinstall cycles; (3) cleanroom and pharma validation \u2014 clamp-mount removes shaft-marking as a contamination-risk source. For applications where none of these factors apply, the corresponding EP6-40 set-screw variant is the more economical specification.<\/p>\n<\/details>\n<details style=\"background:#f5f3ff; border:1px solid #c4b5fd; border-radius:calc(0.4em); padding:calc(1.5%); margin-bottom:calc(0.6em);\">\n<summary style=\"cursor:pointer; font-weight:bold; color:#5b21b6; padding:calc(0.5em);\">What is the documented M5 clamp-bolt torque specification?<\/summary>\n<p style=\"padding:calc(0.5em);\">The standard M5 clamp-bolt torque is 6 N\u00b7m for property class 12.9 hardware. Lower-class hardware (e.g., property class 8.8) requires reduced torque (4 N\u00b7m). For A4-80 stainless clamp-bolt variants, torque is 5 N\u00b7m. Over-torque can cause aluminum hub yield and reduce clamp-effectiveness; under-torque produces hub-to-shaft slip under load. Calibrated torque-wrench installation is recommended for production environments.<\/p>\n<\/details>\n<details style=\"background:#f5f3ff; border:1px solid #c4b5fd; border-radius:calc(0.4em); padding:calc(1.5%); margin-bottom:calc(0.6em);\">\n<summary style=\"cursor:pointer; font-weight:bold; color:#5b21b6; padding:calc(0.5em);\">How many removal-and-reinstall cycles does the clamp-mount support?<\/summary>\n<p style=\"padding:calc(0.5em);\">Documented clamp-mount cycle life is unlimited at the specified 6 N\u00b7m clamp-bolt torque. The split-collar clamp section returns to its dimensional baseline upon bolt loosening, and the clamping action is repeatable across an indefinitely large number of cycles without measurable wear. For applications expecting more than 1 000 cycles per service life, periodic inspection of the clamp-bolt threads for wear is recommended.<\/p>\n<\/details>\n<details style=\"background:#f5f3ff; border:1px solid #c4b5fd; border-radius:calc(0.4em); padding:calc(1.5%); margin-bottom:calc(0.6em);\">\n<summary style=\"cursor:pointer; font-weight:bold; color:#5b21b6; padding:calc(0.5em);\">Is the EP6C-40 suitable for SEMI standard cleanroom environments?<\/summary>\n<p style=\"padding:calc(0.5em);\">Yes. The POM-C slider material is approved for cleanroom installation (ISO 14644 Class 5 \/ SEMI Class 100) with documented particulate-emission profile. The aluminum hub material is anodised, eliminating bare-aluminum oxide-shedding pathways. For installations requiring the highest cleanroom-class (ISO 14644 Class 1, Class 10 SEMI), full-coupling particulate-emission certification is supplied on request.<\/p>\n<\/details>\n<details style=\"background:#f5f3ff; border:1px solid #c4b5fd; border-radius:calc(0.4em); padding:calc(1.5%); margin-bottom:calc(0.6em);\">\n<summary style=\"cursor:pointer; font-weight:bold; color:#5b21b6; padding:calc(0.5em);\">Can the EP6C-40 be specified for ATEX or static-sensitive electronics manufacture?<\/summary>\n<p style=\"padding:calc(0.5em);\">Yes \u2014 specify the anti-static carbon-filled POM-C slider variant. This provides a documented surface-resistance under 10\u2076 \u03a9, preventing static-electricity buildup at the metallic interfaces. The variant is appropriate for ATEX Zone 2 installations and for static-sensitive semiconductor-manufacture environments. ATEX Zone 1 deployments require additional engineering review.<\/p>\n<\/details>\n<h3 style=\"color:#5b21b6; font-size:clamp(17px,2.5vw + 10px,22px); margin-top:calc(1.2em);\">Quote EP6C-40 for Precision Larger-Servo Drives<\/h3>\n<p>For medical-imaging, semiconductor front-end, robotic-joint, higher-end CNC auxiliary, and pharma tablet-press indexing applications, the EP6C-40 is Ever-power&#8217;s preferred precision clamp-hub specification across the larger-bore servo range. Browse the wider <a href=\"https:\/\/oldhamcoupling.net\/pl\/products\/\" style=\"color:#5b21b6; text-decoration:underline;\">EP6C clamp series catalogue<\/a>, read about <a href=\"https:\/\/oldhamcoupling.net\/pl\/about-us\/\" style=\"color:#5b21b6; text-decoration:underline;\">Ever-power&#8217;s precision-coupling capability<\/a>, or move directly to a B2B enquiry below.<\/p>\n<p style=\"text-align:center; padding:calc(1.5em) 0;\">\n  <a href=\"https:\/\/oldhamcoupling.net\/pl\/contact-us\/\" style=\"display:inline-block; background:#5b21b6; color:#fff; padding:calc(0.8em) calc(2em); text-decoration:none; border-radius:calc(0.4em); font-weight:bold; font-size:clamp(15px,2vw + 10px,18px);\">Quote EP6C-40 \u2192<\/a>\n<\/p>\n<p><script type=\"application\/ld+json\">{\n    \"@context\": \"https:\\\/\\\/schema.org\",\n    \"@graph\": [\n        {\n            \"@type\": \"Product\",\n            \"name\": \"EP6C-40 Precision Clamp Oldham Coupling\",\n            \"sku\": \"EP6C-40\",\n            \"description\": \"40 mm aluminum-hub clamp Oldham coupling rated 9 N\\u00b7m continuous \\\/ 18 N\\u00b7m peak at 3600 rpm; bores 12-16 mm. Medical imaging, semiconductor front-end, robotic joints, CNC auxiliary, pharma indexing drives.\",\n            \"category\": \"Clamp Oldham Couplings\",\n            \"image\": \"https:\\\/\\\/oldhamcoupling.net\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/clamp-oldham-coupling.webp\",\n            \"brand\": {\n                \"@type\": \"Brand\",\n                \"name\": \"Ever-power\"\n            }\n        },\n        {\n            \"@type\": \"FAQPage\",\n            \"mainEntity\": [\n                {\n                    \"@type\": \"Question\",\n                    \"name\": \"Clamp-mount vs set-screw choice?\",\n                    \"acceptedAnswer\": {\n                        \"@type\": \"Answer\",\n                        \"text\": \"Clamp-mount for hardened shafts (HRC>50), shaft-mark elimination, cleanroom\\\/pharma validation; set-screw EP6-40 for cost-sensitive light-duty.\"\n                    }\n                },\n                {\n                    \"@type\": \"Question\",\n                    \"name\": \"M5 clamp-bolt torque specification?\",\n                    \"acceptedAnswer\": {\n                        \"@type\": \"Answer\",\n                        \"text\": \"6 N\\u00b7m for class 12.9; 4 N\\u00b7m for 8.8; 5 N\\u00b7m for A4-80 stainless. Calibrated torque-wrench recommended.\"\n                    }\n                },\n                {\n                    \"@type\": \"Question\",\n                    \"name\": \"Removal-and-reinstall cycle life?\",\n                    \"acceptedAnswer\": {\n                        \"@type\": \"Answer\",\n                        \"text\": \"Unlimited at specified 6 N\\u00b7m torque; clamp-section returns to baseline indefinitely; inspect threads above 1000 cycles.\"\n                    }\n                },\n                {\n                    \"@type\": \"Question\",\n                    \"name\": \"SEMI cleanroom compatibility?\",\n                    \"acceptedAnswer\": {\n                        \"@type\": \"Answer\",\n                        \"text\": \"Yes \\u2014 POM-C slider approved ISO 14644 Class 5 \\\/ SEMI Class 100; anodised aluminum hubs; full certification for Class 1\\\/10 on request.\"\n                    }\n                },\n                {\n                    \"@type\": \"Question\",\n                    \"name\": \"ATEX or static-sensitive deployment?\",\n                    \"acceptedAnswer\": {\n                        \"@type\": \"Answer\",\n                        \"text\": \"Anti-static carbon-filled POM-C variant; <10^6 \\u03a9 surface resistance; ATEX Zone 2 suitable, Zone 1 requires engineering review.\"\n                    }\n                }\n            ]\n        }\n    ]\n}<\/script><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p style=\"font-size:clamp(14px,2vw + 10px,18px); line-height:1.6; word-break:break-word; overflow-wrap:break-word;\">The EP6C-40 <strong>precision clamp Oldham coupling<\/strong> rates 9 N\u00b7m continuous \/ 18 N\u00b7m peak at 3 600 rpm for shafts 12\u201316 mm. Larger-servo medical imaging, semiconductor front-end equipment, and high-end CNC machine indexing axes.<\/p>","protected":false},"featured_media":669,"comment_status":"closed","ping_status":"open","template":"","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[552],"product_tag":[515,658,656,659,657,660],"class_list":["post-783","product","type-product","status-publish","has-post-thumbnail","product_cat-clamp-oldham-couplings","product_tag-16mm-shaft-coupling","product_tag-18-nm-coupling","product_tag-ep6c-40-oldham-coupling","product_tag-medical-imaging-coupling","product_tag-precision-clamp-coupling","product_tag-semiconductor-coupling","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/oldhamcoupling.net\/pl\/wp-json\/wp\/v2\/product\/783","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/oldhamcoupling.net\/pl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/oldhamcoupling.net\/pl\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/oldhamcoupling.net\/pl\/wp-json\/wp\/v2\/comments?post=783"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/oldhamcoupling.net\/pl\/wp-json\/wp\/v2\/media\/669"}],"wp:attachment":[{"href":"https:\/\/oldhamcoupling.net\/pl\/wp-json\/wp\/v2\/media?parent=783"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/oldhamcoupling.net\/pl\/wp-json\/wp\/v2\/product_brand?post=783"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/oldhamcoupling.net\/pl\/wp-json\/wp\/v2\/product_cat?post=783"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/oldhamcoupling.net\/pl\/wp-json\/wp\/v2\/product_tag?post=783"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}